Why a standard was needed
By the late nineteenth century, copper wire was carrying telegraph signals, telephone calls and electric power across rapidly growing networks. Buyers needed a reliable way to judge quality, because small amounts of impurities, even a fraction of a per cent of elements such as phosphorus, arsenic or iron, could sharply reduce copper’s ability to carry current. Different countries and manufacturers used different reference values, which made comparisons and contracts difficult. In 1913, the International Electrotechnical Commission adopted the International Annealed Copper Standard, known as IACS. It defined the resistance of a specified copper wire at 20 °C and declared that copper’s conductivity to be 100%. Every other conductor could then be compared directly with it.
What the number means
A conductivity rating in IACS is a simple percentage. A metal at 50% IACS conducts electricity half as well as the reference copper for the same shape and size, so a wire made from it would need roughly twice the cross-sectional area to carry the same current with the same losses. The reference value corresponds to a resistivity of about 1.72 microhm-centimetres. Annealed means the copper has been heated and slowly cooled to soften it and remove the effects of cold working, which slightly increases resistance. Specifying the condition was important, because hard-drawn copper wire straight from the drawing dies conducts a little less well than soft, annealed wire.
Better than the benchmark
Refining has improved since 1913. The copper of that era was about as pure as industry could reliably make, so its conductivity seemed a natural ceiling. Modern electrolytically refined copper is purer, and the common grade used for electrical wiring typically reaches about 101% IACS, slightly exceeding the original reference. Specialist oxygen-free copper may rate a little higher still. This shows that the standard is a fixed yardstick rather than a statement about the best possible copper. The only common metal that conducts better is silver, at around 105% IACS, but its cost restricts it to specialist uses such as certain contacts, conductive pastes and high-frequency components.
How other metals compare
Against the copper standard, gold rates at roughly 70% IACS, valued for corrosion-free contacts rather than for raw conductivity. Aluminium comes in at about 61%, while iron and common steels rank far lower, generally below about 20% and often much less, depending on composition. Stainless steel conducts poorly, at only a couple of per cent. Alloying generally reduces conductivity: brass, a copper-zinc alloy, rates around a quarter to a third of pure copper. That is why electrical cables use nearly pure copper, while alloys are reserved for parts where strength, wear resistance or spring properties matter more than carrying current, such as connectors and switch components.
The aluminium trade-off
If copper conducts better, why are many overhead power lines made of aluminium? The answer is weight. Aluminium is about 70% less dense than copper, so although an aluminium conductor must be thicker to carry the same current, it weighs roughly half as much. For long spans hanging between towers, that saving matters, and aluminium is also much cheaper per tonne. Such lines often include a steel core for strength. Inside buildings, vehicles and electronic devices, where space is limited and connections must be compact and reliable, copper usually wins. Engineers across the Gulf’s expanding power grids make exactly these trade-offs when choosing between the two metals for different parts of the network.
Why the yardstick endures
More than a century after its adoption, IACS remains in daily use in specifications, testing laboratories and trade contracts, even though conductivity can also be expressed in scientific units such as megasiemens per metre. Its persistence reflects copper’s central role in electrical engineering: when the world electrified, copper was the material of choice, and it still dominates wiring, motors, transformers and electronics. Conductivity tests using eddy currents also help verify materials and sort scrap, since different alloys produce different readings. The standard is a quiet reminder that measurement systems often grow out of practical industries, and that a single well-chosen reference can organise an entire field for generations.
Sources & further reading
Figures are rounded and widely published; check the linked organisations for the latest editions. These organisations do not endorse this website.