01

Capacity is not output

Power plants are usually described by their capacity, the maximum power they can produce, measured in megawatts or gigawatts. But capacity says nothing about how many hours a plant actually runs at that level. A 1,000-megawatt plant running non-stop for a year would generate 8,760 gigawatt-hours, but real plants rarely come close. The ratio between actual output and that theoretical maximum is the capacity factor. It is one of the most useful and most overlooked numbers in energy. Without it, announcements that a country has added a certain number of gigawatts of a technology can easily mislead readers about how much electricity that capacity supplies.

02

Typical values

Capacity factors vary widely by technology and location. Nuclear plants in the United States have averaged more than 90 per cent in recent years, because they run continuously except during refuelling and maintenance. Combined-cycle gas plants vary, often between about 40 and 60 per cent, depending on how much they are needed. Onshore wind farms commonly reach 25 to 40 per cent, and offshore wind can exceed 40 to 50 per cent in strong-wind seas. Solar photovoltaic plants typically range from about 10 per cent in cloudy northern Europe to around 25 per cent or more in sunny deserts with tracking systems that follow the sun.

03

A Gulf comparison

Consider two plants in the UAE with the same rated capacity, 1,000 megawatts each. A solar farm with a 25 per cent capacity factor produces about 2,200 gigawatt-hours a year. A nuclear unit, such as one of the four at Barakah, running at about 90 per cent would produce roughly 7,900 gigawatt-hours, more than three times as much. This does not mean nuclear is better; solar may still be cheaper per unit of electricity, and its output peaks in sunny afternoons when cooling demand is high. It does mean that matching the annual output of one nuclear unit requires several times as much solar capacity, along with storage.

04

Why capacity factors differ

There are three main reasons. First, the availability of the energy resource: the sun sets and the wind drops. Second, maintenance and breakdowns, which take any plant offline for part of the year. Third, economics and dispatch decisions: grid operators run the cheapest available plants first, so expensive peaking plants may run only a few hundred hours a year, giving very low capacity factors by design. Policies also play a role. When there is too much wind or solar for the grid to absorb, output may be curtailed, lowering capacity factors. Improvements in technology, such as taller wind turbines, can raise them.

05

Common misunderstandings

A low capacity factor is not necessarily a sign of failure. Peaking gas turbines that run only during demand spikes are valuable precisely because they are available when needed. Similarly, solar’s capacity factor is limited by the length of the day, not by poor design. Another misunderstanding is treating capacity factor as efficiency. Efficiency measures how much input energy a plant converts into electricity; capacity factor measures how much of the time it operates at full power. A highly efficient gas plant can have a low capacity factor if it is seldom needed, and a solar panel with modest efficiency can run every sunny day.

06

How to use the number

When reading energy news, convert capacity into likely output using a reasonable capacity factor before comparing technologies or countries. A headline about thousands of megawatts of new solar is impressive, but the annual electricity it supplies depends on location and design. Planners also look at ‘capacity credit’, the share of a plant’s capacity that can be relied on during peak demand, which may differ from its average capacity factor. Combining both measures helps explain why power systems need a mix of resources. Megawatts describe potential; megawatt-hours describe what the lights, air conditioners, desalination plants and factories actually receive, day after day.

FOLLOW THE EVIDENCE

Sources & further reading

Figures are rounded and widely published; check the linked organisations for the latest editions. These organisations do not endorse this website.