Water as a signal
The human body is mostly water, and every water molecule contains two hydrogen atoms. The nucleus of each hydrogen atom is a single proton, which behaves like a tiny spinning magnet. Normally these magnets point in random directions. Magnetic resonance imaging, or MRI, exploits them. By measuring how hydrogen nuclei in different tissues respond to magnetism and radio waves, a scanner can distinguish fat, muscle, fluid, grey and white brain matter, and tumours or inflammation, often in far greater detail than X-rays or CT scans can for soft tissues. It does so without ionising radiation, which is why MRI is widely used for the brain, spine, joints and many organs.
A very strong magnet
The heart of a scanner is a large superconducting magnet wrapped around the tunnel where the patient lies. Most hospital machines produce fields of 1.5 or 3 tesla. Earth’s magnetic field at the surface is about 50 microtesla, so a 1.5-tesla scanner is about 30,000 times stronger. To carry the huge currents needed without resistance, the magnet’s coils are cooled with liquid helium to about minus 269 degrees Celsius, just above absolute zero. The field is always on, even when no one is being scanned. That is why staff check carefully for metal before anyone enters the room: loose objects can be pulled into the magnet with dangerous force.
Radio pulses and echoes
Inside the field, hydrogen nuclei line up and wobble, or precess, at a precise frequency that depends on the magnet’s strength: about 64 megahertz at 1.5 tesla and 128 megahertz at 3 tesla, in the range of FM radio. The scanner transmits a short pulse at exactly that frequency, which knocks the nuclei out of alignment. When the pulse stops, they relax back, emitting faint radio signals picked up by coils placed around the body. Different tissues relax at different rates, measured as times called T1 and T2. By adjusting the timing of pulses, radiographers can make fat, water or particular abnormalities appear bright or dark, revealing contrast that other methods miss.
Finding where signals come from
To build a picture, the scanner must know where each signal originates. It uses additional gradient coils that make the magnetic field slightly stronger at one end of the body than the other, along three directions. Because the nuclei’s frequency depends on field strength, each position emits at a subtly different frequency and phase. A computer then uses a mathematical technique called the Fourier transform to unpick the mixture of signals into a detailed image, slice by slice. The gradient coils switch on and off rapidly, and the forces on them produce the loud knocking and buzzing sounds patients hear, which is why earplugs or headphones are provided during a scan.
From discovery to hospital
Nuclear magnetic resonance was discovered in the 1940s by physicists studying atomic nuclei, and chemists used it for decades to analyse molecules. In the early 1970s, Paul Lauterbur in the United States and Peter Mansfield in Britain showed how gradients could turn the signals into images, work that earned them the 2003 Nobel Prize in Physiology or Medicine. Raymond Damadian, who had found that tumours produce different signals, built one of the first whole-body scanners, producing a human image in 1977. Clinical MRI spread rapidly in the 1980s. The word ‘nuclear’ was dropped from its name partly because patients associated it with radiation, which MRI does not use.
Limits and safety
MRI has trade-offs. Scans take longer than CT, often 20 to 60 minutes, and patients must lie still in a narrow, noisy tunnel, which some find claustrophobic; wider-bore and open designs help. Some pacemakers, implants and metal fragments are unsafe in the field, so screening questionnaires are essential, although many modern implants are designed to be compatible. Some scans use a contrast agent containing gadolinium to highlight blood vessels or lesions. The machines are expensive to buy and run, and helium supplies are a concern. Anyone with questions about whether an MRI is right for them should discuss it with their doctor or the radiology team.
Sources & further reading
- US National Institute of Biomedical Imaging and Bioengineering · Magnetic resonance imaging ↗
- NHS · MRI scan ↗
- Nobel Prize · Physiology or Medicine 2003 ↗
Figures are rounded and widely published; check the linked organisations for the latest editions. These organisations do not endorse this website.