Shaking from below
Earthquakes do not usually kill people directly; collapsing buildings do. When the ground lurches sideways, the base of a building moves with it, but the floors above lag behind because of their inertia. That difference creates large sideways forces in columns, walls and joints, which most buildings were originally designed only to carry downwards. The forces depend on the building’s mass, the strength of shaking and how the structure responds. Earthquake engineering, which grew rapidly after disasters in California, Japan and elsewhere in the 20th century, aims to keep those forces manageable and to make sure that, if something must give, it gives slowly and safely rather than suddenly.
Resonance and natural period
Every building has a natural period, the time it takes to sway back and forth once if pushed. A useful rule of thumb is about a tenth of a second per storey, so a 10-storey building takes about one second and a 40-storey tower about four. If the ground shakes at a similar rhythm, the building resonates, swinging further with each cycle, like a child on a swing pushed in time. Earthquakes release a mix of frequencies, and the soil beneath a site can amplify some of them. Engineers therefore study local ground conditions and design buildings whose periods, strength and damping avoid dangerous resonance with the shaking expected there.
Isolating the building
One powerful approach is base isolation. Instead of fixing a building rigidly to its foundations, engineers set it on bearings, often made from layers of rubber and steel with a lead core, or on curved sliding plates. These are stiff vertically, so they carry the building’s weight, but flexible sideways. During an earthquake the ground moves beneath the bearings while the building above moves much more slowly and gently, because isolation stretches its natural period to two or three seconds, away from the strongest shaking. Hospitals, emergency centres and historic buildings in Japan, New Zealand, Chile and the United States use isolation so they can keep operating after a major quake.
Dampers and ductility
Dampers work like shock absorbers. Fluid-filled cylinders, metal parts designed to yield, or friction devices are fitted into a building’s frame and turn the energy of motion into heat, reducing how far and how long it sways. Equally important is ductility: the ability of a structure to bend and stretch well beyond its elastic limit without breaking. Steel and properly reinforced concrete can do this if designed carefully, with closely spaced steel ties around columns and strong connections. Engineers deliberately choose where damage should occur, usually in beams rather than columns, so that a building may be badly bent after a severe earthquake yet still standing, letting everyone get out.
What building codes require
Modern seismic codes do not promise that buildings will be undamaged. For ordinary structures, the aim is usually that they suffer little damage in frequent small earthquakes and do not collapse in rare, severe ones, protecting lives even if the building must later be demolished. Critical buildings such as hospitals face stricter rules. Codes divide regions into hazard zones based on the expected shaking. The UAE has a moderate seismic hazard, mainly from earthquakes in the mountains of southern Iran, and its building regulations require seismic design. Tall towers on soft coastal ground deserve particular attention, because distant earthquakes can produce slow, long-period shaking that affects high-rise buildings most.
Lessons from failures
Much of what engineers know was learned from collapses. Buildings with an open ground floor of shops or parking, sometimes called a soft storey, have repeatedly failed because that floor was much weaker than those above. Unreinforced brick and stone buildings, common in older towns, are especially vulnerable. Poor construction, missing steel ties or weak concrete can defeat a good design, which is why inspection and enforcement matter as much as the code itself. Retrofitting existing buildings, by adding steel braces, walls or wrapped columns, is expensive but saves lives. Since earthquakes cannot be predicted, the most reliable protection is to build and strengthen structures before the ground starts to move.
Sources & further reading
Figures are rounded and widely published; check the linked organisations for the latest editions. These organisations do not endorse this website.